Parameter Typical Values / Options
Flow / Capacity 100–1,000 LPH (litres per hour) or equivalent GPD (gallons per day)
Feed Water Quality Requirements • TDS up to ~1,000–1,500 ppm
• Turbidity < ~1 NTU
• Hardness (as CaCO₃) depending on pretreatment – softer water preferred
• Chlorine residual low or removed; iron & manganese minimal
• pH ~6.5–8.5 (typical acceptable range)
Recovery Ratio ~40–60% depending on quality of feed water and system design
Salt Rejection ~90–98% for commercial membranes under good conditions
Operating Pressure ~7–15 bar (≈100–220 psi) for brackish or municipal feed water systems
Pre-Filtration Stages Sediment filter (micron cartridge), carbon filter, multimedia or dual media filter; optional softening depending on feed hardness
Instrumentation & Controls Pressure gauges, flow meters, TDS monitor, auto shutdown (low/high pressure), manual & flushing options
Materials FRP or SS304/SS316 for membrane housings; polymer/PP for filters; corrosion-resistant, durable casing
Electrical / Power Requirements 220–240V single phase (for small/commercial units) or three-phase for higher capacity; motor/pump sized accordingly